Ventis HEI170 Wood Insert

by Ventis
In-Store Only

View Product Brochure

Units in stock - Contact one of our offices for more information

▪Medium size wood insert suitable for smaller spaces
▪EPA certified at only 1.26 g/h
▪Solidity and manufacturing quality
▪Non-catalytic combustion technology
▪Installation authorized on the Island of Montreal
▪Cast iron door
▪144 CFM blower
▪Stainless steel heat shield added to the firestop

View More Information  

GENERAL FEATURES

Fuel type Dry cordwood (16" recommended)
Recommended heating area (9) 500 - 1,800 ft²
Overall firebox volume 1.9 ft³
EPA loading volume 1.44 ft³
Maximum burn time (9) 6 h
Maximum heat output-dry cordwood (4) 65,000 BTU/h
Minimum overall heat output rate (4) (5) 15,650 BTU/h (4.6 kW)
Maximum overall heat output rate (4) (5) 23,300 BTU/h (6.83 kW)
Average overall efficiency-dry cordwood (HHV) (5) (6) 70 %
Average overall efficiency-dry cordwood (LHV) (5) (7) 75 %
Optimum efficiency (1) (2) 78 %
Optimum heat transfer efficiency (8) 74 %
Average particulate emission rate (3) 1.26 g/h
Average CO (10) 58 g/h

  • 1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
  • 2. Optimum overall efficiency at a specific burn rate (LHV).
  • 3. This appliance is officially tested and certified by an independent agency.
  • 4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
  • 5. As measured per CSA B415.1-10 stack loss method.
  • 6. Higher Heating Value of the fuel.
  • 7. Lower Heating Value of the fuel.
  • 8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
  • 9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
  • 10. Carbon monoxide.